CROP PROCESSING - CLEANING Primary cleaning Sensing system Fan speed sensor - Short circuit to B+ (K.62.B.95.52 - G.30.B.54) AFX8010 E0013-03 - Cleaning Fan Speed Sensor Cause: The cleaning fan RPM sensor (B16) circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "FAN SPD SEN" to check the voltage range. The proper voltage sensor blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal- 0.5 - 5.6 volts A.
If the voltage reading is high out of range continue with Step 2 . B. If the voltage reading is within the proper limits, since the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 4 . 2. Disconnect the cleaning fan RPM sensor connector X089 . A. If the voltage drops to 7.3 - 9.0 volts the short is in the sensor, or sensor wiring. Replace the sensor. B. If the voltage remains high, continue with Step 3 . 3. Disconnect the front frame (FF) harness from the lower frame (LF) harness at connector X023 . A. If the voltage drops to 7.3 - 9.0 volts , the short is in the lower frame (LF) harness between connector X023 and connector X089 wire 404 yellow.
Locate the short and repair. B. If the voltage remains high, the short circuit is in the front frame (FF) harness between connector X023 and connector X020 pin J3-13 wire 404 yellow. Locate the short and repair. 4. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9717 1 27/05/2004 K.62.B / 156