CROP PROCESSING - CLEANING Primary cleaning Sensing system Fan speed sensor - Short circuit to ground (K.62.B.95.52 - G.30.B.53) AFX8010 E0013-04 - Cleaning Fan Speed Sensor Cause: The cleaning fan RPM sensor (B16) circuit is shorted to ground. Possible failure modes: 1. Sensor signal wiring shorted to ground. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "FAN SPD SEN" to check the voltage range. The proper voltage sensor blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal - 0.5 - 5.6 volts A.
If the voltage reading is 0 - 0.5 volts continue with Step 2 . 2. Disconnect the cleaning fan RPM sensor connector X089 . B. If the voltage reading is within the proper limits. Continue the troubleshooting at Step 4 . A. If the voltage increases to 7.3 - 9.0 volts the short is in the sensor, or sensor wiring. Replace the sensor. 3. Disconnect the lower frame (LF) harness from the front frame harness (FF) at connector X023 . B. If the voltage remains low, continue with Step 3 . A. If the voltage increases to 7.3 - 9.0 volts , the short is in the lower frame (LF) harness between connector X023 and connector X089 wire 404 yellow. Locate the short and repair. B.
If the voltage remains low, the short circuit is in the front frame (FF) harness between connector X023 and connector X020 J3-13 wire 404 yellow. Locate the short and repair. 4. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9717 1 27/05/2004 K.62.B / 159