CROP PROCESSING - CLEANING Primary cleaning 7. Disconnect connector X023 . Use a multimeter to check for voltage at connector X023 pin 18. A. If no voltage is found, continue with Step 9 . B. If 12 volts is found, there is an open circuit in the lower frame (LF) harness between connector X023 and connector X089 wire 1259 orange. Locate the open and repair. 8. Disconnect connector X008 . Use a multimeter to check for voltage on the main frame (MF) harness end of connector X008 pin 18. A. If no voltage is found, continue with Step 10 . B. If 12 volts is found, there is an open circuit in the front frame (FF) harness between connector X023 and connector X008 wire 1259 orange or 1205 orange.
Locate the open and repair. 9. Disconnect connector X005 . Use a multimeter to check for voltage on the cab main (CM) harness end of connector X005 pin 5. A. If no voltage is found, there is an open circuit in the cab main (CM) harness between connector X005 and fuse F45 wire 013 orange. Locate the open and repair. B. If 12 volts is found, there is an open circuit in the main frame (MF) harness between connector X005 and connector X008 wire 1205 orange or 013 orange. Locate the open and repair. 10. Disconnect connector X023 . Install a jumper wire between pins 7 and 16 on connector X023 . A.
If the voltage drops to 0 - 0.5 volts there is an open circuit in the lower frame (LF) harness between connector X023 and X089 wire 404 yellow. Locate the open and repair. B. If the voltage remains at 7.3 - 9.0 volts , there is an open circuit in the front frame (FF) harness between connector X023 and connector X020 J3-13 wire 404 yellow. Locate the open and repair. 11. Visually inspect harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found erase fault code and continue operation. 9717 1 27/05/2004 K.62.B / 163