Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning Sensing system Sieve shake speed sensor - Short circuit to B+ (K.62.B.95.56 - G.30.B.54) AFX8010 E0015-03 - Sieve Shaker Speed Sensor Cause: The sieve shake RPM sensor (B-56) circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "SHAKER SPD SEN" to check the voltage range.

The proper voltage sensor blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal - 0.5 - 5.6 volts A. If the voltage reading is high out of range continue with Step 2 . B. If the voltage reading is within the proper limits, since the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 3 . 2. Disconnect the sieve shake RPM sensor connector X181 . A. If the voltage drops to 7.3 - 9.0 volts the short is in the sensor, or sensor wiring. Replace the sensor. B. If the voltage remains high, the short circuit is in the main frame (MF) harness between connector X181 and connector X019 J2-38 wire 1162 yellow. 3.

Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9717 1 27/05/2004 K.62.B / 167