Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning Sensing system Sieve shake speed sensor - Open circuit (K.62.B.95.56 - G.30.B.50) AFX8010 E0015-05 - Sieve Shaker Speed Sensor Cause: The sieve shake RPM sensor (B-56) circuit is open. Possible failure modes: 1. Sensor supply wiring is open. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "SHAKER SPD SEN" to check the voltage range.

The proper voltage for sensor unblocked by ferrous metal is 0.5 - 5.6 volts The proper voltage for sensor blocked by ferrous metal is 5.6 - 7.3 volts The proper voltage with sensor disconnected is 7.3 - 9.0 volts . A. If the voltage reading is high, 7.3 - 9.0 volts continue with Step 2 . B. If the voltage reading is within the proper limits, the open is not present at this time. Continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.

Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the sieve shake RPM sensor connector X181 . Use a jumper wire to short the harness end of connector X181 pin 2 to chassis ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is not in the supply side of the circuit. Continue with Step 3 . B. If the monitor still displays 7.3 - 9.0 volts , the open circuit is in the main frame (MF) harness between connector X181 pin 2 and connector X019 pin J2-38 wire 1162 yellow. Locate the open and repair. 3. Disconnect the sieve shake RPM sensor connector X181 .

Use a multimeter to check for continuity between the harness end of connector X181 pin 1 and chassis ground. A. If there is continuity, the ground path for the sensor is complete, and the fault is in the sensor itself. Replace the sensor. B. If there is no continuity, the open circuit is in the main frame (MF) harness between connector X181 pin 1 and connector X019 pin J2-14 wire 1191 blue or 460 blue. Locate the open and repair. 4. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the error code and continue operation. 9717 1 27/05/2004 K.62.B / 173