CROP PROCESSING - CLEANING Tailings return system Sensing system Tailing speed sensor - Short circuit to B+ (K.62.C.95.80 - G.30.B.54) AFX8010 E0018-03 - Tailings Speed Sensor Cause: The tailing RPM sensor (B-39) circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "TAILINGS SPD SEN" to check the voltage range. The proper voltage sensor blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal - 0.5 - 5.6 volts A.
If the voltage reading is high out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 3 . 2. Disconnect the tailing RPM sensor connector X186 . A. If the voltage drops to 7.3 - 9.0 volts , the short is in the sensor, or sensor wiring. Replace the sensor. B. If the voltage remains high, the short circuit is in the main frame (MF) harness between connector X186 and connector X019 J2-37 wire 441 yellow. Locate the short and repair. 3. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A.
If no damage is found, erase the fault code and continue operation. 9718 1 27/05/2004 K.62.C / 3