CROP PROCESSING - CLEANING Tailings return system Sensing system Tailing speed sensor - Open circuit (K.62.C.95.80 - G.30.B.50) AFX8010 E0018-05 - Tailings Speed Sensor Cause: The tailing RPM sensor (B-39) circuit is open. Possible failure modes: 1. Sensor supply wiring is open. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "TAILINGS SPD SEN" to check the voltage range.
The proper voltage for sensor unblocked by ferrous metal is 0.5 - 5.6 volts The proper voltage for sensor blocked by ferrous metal is 5.6 - 7.3 volts The proper voltage with sensor disconnected is 7.3 - 9.0 volts . A. If the voltage reading is high 7.3 - 9.0 volts , continue with Step 2 . B. If the voltage reading is within the proper limits, the open is not present at this time. Continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.
Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the tailing RPM sensor connector X186 . Use a jumper wire to short the harness end of connector X186 pin 2 to chassis ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is not in the supply side of the circuit. Continue with Step 3 . B. If the monitor still displays 7.3 - 9.0 volts , the open circuit is in the main frame (MF) harness between connector X186 pin 2 and connector X019 pin J2-37 wire 441 yellow. Locate the open and repair. 3. Disconnect the tailing RPM sensor connector X186 .
Use a multimeter to check for continuity between the harness end of connector X186 pin 1 and chassis ground. A. If there is continuity, the ground path for the sensor is complete, and the fault is in the sensor itself. Replace the sensor. B. If there is no continuity, there is an open circuit in the main frame (MF) harness between connector X186 pin 1 and connector X019 pin J2-14 wire 442 blue, 401 blue or 460 blue. Locate the open and repair. 4. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9718 1 27/05/2004 K.62.C / 9