Case IH AFX8010 — CLEANING Tailings return system

CROP PROCESSING - CLEANING Tailings return system Sensing system Tailing volume sensor - Open circuit (K.62.C.95.81 - G.30.B.50) AFX8010 E0147-05 - Tailings Volume Sensor Cause: The tailings volume sensor (R-24) circuit is open or shorted to ground. Possible failure modes: 1. Sensor signal wiring is open or shorted to ground. 2. Loss of power to the sensor. 3. Module internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "TAILINGS VOL SEN" to check the voltage range.

Remove the cover from the bottom of the returns cross auger tube, and carefully move the arm on the tailings volume sensor while monitoring the voltage; the voltage should stay within range, and should change smoothly with movement of the sensor arm. The proper voltage range is 0.3 - 5.2 volts . A. If the voltage reading is low ( 0.3 volts ) out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the circuit may not be open or shorted to ground at this time. Continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed.

Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect connector X445 , and use a multimeter to test for voltage on connector X445 pin 1. There should be 5 volts present. A. If 5 volts is found, continue with Step 3 . B. If no voltage is found, there is an open circuit in the main frame (MF) harness between connector X445 pin 1 and connector X016 pin J2-31 wire 459 pink or 1200 pink. Locate the open and repair. 3. Disconnect connector X445 . Use a multimeter to check for continuity between connector X445 pin 2 and ground. A.

If no continuity is found, continue with Step 4 . B. If continuity is found, continue with step 4 . 4. Disconnect connector X008 . Use a multimeter to check for continuity between connector X008 pin 30 and ground. A. If no continuity is found, there is a short to ground in the main frame (MF) harness between connector X445 and connector X008 wire 1164 yellow. Locate the open and repair. B. If continuity is found, there is a short to ground in the front frame (FF) harness between connector X008 pin 30 and connector X017 pin J3-22 wire 1164 yellow. Locate the short and repair. 5. Disconnect connector X008 .

Use a multimeter to check for continuity between connector X445 pin 2 and connector X008 pin 30. A. If continuity is found, continue with step 6 . B. If no continuity is found, there is an open circuit in the main frame (MF) harness between connector X445 pin 2 and connector X008 pin 30 wire 1164 yellow. Locate the open and repair. 9718 1 27/05/2004 K.62.C / 18