CROP PROCESSING - CLEANING Self-levelling frame 4. Raise the floor jacks evenly to allow the leveling frame (1) to be positioned above the combine frame (2) just enough to allow bushing removal. 20015185 4 5. Remove the shim washer (1) positioned between the leveling frame (2) and combine frame (3) .. 20015187a 5 6. Remove the two bushings (1) from the leveling frame (2) NOTE: Clean all parts in a suitable solvent and allow to air dry. Inspect the pivot shaft for wear or damage. Repair or replace as necessary. Inspect the leveling frame and combine frame pivot housings for wear or damage. Repair or replace as necessary. 20015186 6 7.
Install two new bushings (1) into the pivot bore (2) of the leveling frame. 20015188 7 9719 1 27/05/2004 K.62.D / 4