CROP PROCESSING - RESIDUE HANDLING Straw chopper Sensing system Speed sensor - Short circuit to B+ (K.64.C.95.80 - G.30.B.54) AFX8010 E0143-03 - Chopper RPM Sensor Cause: The chopper RPM sensor (B-10) circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "RESIDUE" sort menu, and select "CHOPPER SPD SEN" to check the voltage range.
The proper voltage for sensor when blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage for sensor when not blocked by ferrous metal - 0.5 - 5.6 volts The proper voltage sensor disconnected 7.3 - 9.0 volts . A. If the voltage reading is high out of range 9.0 - 10.0 volts , continue with Step 3 . B. If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 4 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. 2.
Disconnect the chopper RPM sensor from the main frame harness at connector X411 . A. If the voltage drops to 7.3 - 9.0 volts , the short is in the sensor, or sensor wiring. Replace the sensor. B. If the voltage remains high, the short circuit is in the main frame (MF) harness between connector X411 pin 2 and connector X016 pin J2-38 wire 413 yellow. 3. Turn the key to ON position. Observing the LED on the harness end side of the sensor, place ferrous metal in front of sensor then remove. The sensor is functioning if LED changes state. A. If the LED does not change state (turn on and off), replace the sensor. B.
If the LED changes state (turns on and off), erase the fault code and continue operation. 9720 1 27/05/2004 K.64.C / 3