Case IH AFX8010 — RESIDUE HANDLING Spreader

CROP PROCESSING - RESIDUE HANDLING Spreader Sensing system Speed sensor - Open circuit (K.64.D.95.80 - G.30.B.50) AFX8010 E0144-05 - Spreader Speed Sensor Cause: The spreader RPM sensor (B-55) circuit is open. Possible failure modes: 1. Sensor supply wiring is open. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "RESIDUE" sort menu, and select "SPREADER SPD SE" to check the voltage range. The proper voltage sensor blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal - 0.5 - 5.6 volts The proper voltage sensor when disconnected - 7.3 - 9.0 volts . A.

If the voltage reading is high 7.3 - 9.0 volts , continue with Step 2 . B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 10 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. 2. Disconnect the spreader RPM sensor connector X383 . Use a jumper wire to short the harness end of connector X383 pin B to ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the sensor or sensor wiring has failed. Replace the sensor. B.

If the monitor still displays 7.3 - 9.0 volts , continue with Step 3 . 3. Disconnect the straw hood rear (SH) harness from the straw hood front (SW) harness at connector X071 . Use a jumper wire to short connector X071 pin 6 to ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, there is an open circuit in the straw hood rear (SH) harness between connector X071 and the connector X383 pin B wire 414 yellow. Locate the open and repair. B. If the monitor still displays 7.3 - 9.0 volts , continue with Step 4 . 4. Disconnect the straw hood front (SW) harness from the main frame (MF) harness at connector X024 . Use a jumper wire to short connector X024 pin 3 to ground. A.

If the voltage drops to 0 - 0.5 volts indicating a ground, there is an open circuit in the straw hood front (SW) harness between connector X071 and the connector X024 wire 414 yellow. Locate the open and repair. B. If the voltage drops to 0 - 0.5 volts indicating a ground, there is an open circuit in the main frame (MF) harness between connector X024 and connector X016 pin J2-28 wire 414 yellow. Locate the short and repair. 5. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9721 1 27/05/2004 K.64.D / 27