Case IH AFX8010 — UNLOADING Grain unloading

CROP PROCESSING - UNLOADING Grain unloading Command valve Unload engage - Short circuit to B+ (K.72.B.12.21 - G.30.B.54) AFX8010 E0177-03 - Unloader Current Sense Context: The Unloader Current Sense circuit is the ground path for the unload tube clutch PWM solenoid. By monitoring current flow on the return path of the unload tube clutch solenoid, the module can provide precise control of the solenoid engagement. When this error message is reported, this is an indication of excessive current draw on the circuit, or a result of a high voltage short on the return line. Cause: The Unload tube clutch (L-08) circuit has excessive current draw, or is shorted to a high voltage source.

Possible failure modes: 1. Bad solenoid. 2. Return side wiring shorted to 12 volts . 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "UNLOADING" sort menu, and select "UNLOADER ISENSE" to monitor the current flow. Use the "COMMAND" and "ENGAGE" functions to power the circuit at 100% output. The proper unload tube clutch solenoid current should be approximately 1.0 - 1.5 amps . The fault code is triggered by current flow greater than 3.3 amps . A. If the reading is greater than 3.3 amps , continue with Step 3 . B. If the reading is normal ( 1.0 - 1.5 amps ), continue the troubleshooting at Step 8 . C.

If there is no current reading, the module may have failed as a result of a 12V short on the Isense circuit. Continue with Step 6 . NOTE: If the current reading is high, immediately shut off the circuit by pressing the "Enter" key after verifying the reading to prevent module damage. 2. Turn the key switch to the OFF position and disconnect the unload tube clutch solenoid connector X449 . Use a multimeter to check the resistance of the unload cross auger solenoid L08 between connector X449 pins A & B. The proper resistance range for the unload tube clutch solenoid is 7.2 - 11.2 ohms . A. If out of specification, replace the solenoid. Continue with Step 8 . B.

If the coil is within specification, continue with Step 4 . 3. Disconnect connector X011 . Use a multimeter to check the resistance of the unload tube clutch solenoid circuit between connector X011 pins 18 & 19. The resistance should be the same as, or slightly higher than the resistance of the solenoid as measured in Step 3. A. If the resistance is lower than the previously measured resistance, there is a short in the harness between connector X449 and connector X011 wires 568 white and 601 blue. Locate the short and repair. Continue with Step 8 . 4. Carefully disconnect connector X016 on the bottom of CCM2 module.

Use a multimeter to check the resistance of the unload tube clutch solenoid circuit between connector X016 pins J2-4 & J2-20. B. If the resistance is the same as previously measured, continue with Step 5 . 9723 1 27/05/2004 K.72.B / 61