CROP PROCESSING - UNLOADING Grain unloading Command valve Unload swing - Unidentified failure (K.72.B.12.20 - G.30.B.46) AFX8010 E0194-11 - Unload Tube Out Valve Cause: The unload tube out valve (L-04) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad solenoid. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "UNLOADING" sort menu, and select "TUBE OUT VLV". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A.

If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 9 . 2. Disconnect connector X022 . Use a multimeter to check the resistance of the unload tube out valve coil (L04) between connector X022 pins 3 & 10. The proper resistance range is 3 - 5 ohms . A. If there is zero resistance, the unload tube out solenoid is shorted internally. Replace the solenoid. B. If there is infinite resistance, the unload tube out solenoid is open. Replace the solenoid. C. If the resistance is correct, continue with Step 3 . 3.

Use a multimeter to check for continuity between connector X022 pin 3 (MF harness side) and chassis ground. Flex the main frame (MF) harness while making this check. A. If there is continuity to ground, the short to ground is in the main frame (MF) harness between connector X022 and connector X016 pin J2-16 wire 573 white. Locate the short and repair. B. If there is no continuity to ground, continue with Step 5 . 4. Use a multimeter to check for continuity between connector X022 pin 10 (harness side) and chassis ground. Flex the main frame (MF) harness while making this check. A.

If there is no continuity to ground, there is an open circuit in the main frame (MF) harness between connector X022 pin 10 and the front frame ground #2 wire 598 black or 600 black. Locate the open and repair. B. If there is continuity to ground, continue with Step 7 . 5. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the unload tube out valve. Use a multimeter to check for 12 volts between connector X022 pin 3 and chassis ground. A. If 12 volts is not present, there is an open circuit in the main frame (MF) harness between connector X022 pin 3 and connector X016 pin J2-16 wire 573 white. Locate the open and repair. 6.

Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. B. If 12 volts is found, continue with Step 9 . 9723 1 27/05/2004 K.72.B / 72