Case IH AFX8010 — ELECTRICAL POWER SYSTEM

DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM Connector X128 - Cab Roof Harness to HVAC A-09/A-20 10031047D4 186 1.

HVAC module (connector X128) PAC_12110207 187 9667 1 27/05/2004 A.30.A / 98 Cavity Circuit ID Description C1 972 (PU) Backlighting from CCM2 J1-11 through splice block C, W-03 C2 901 (OR) Power from fuse F-49 C3 900 (WH) Output to A/C clutch relay K-10 C4 902 (WH) Output to separator blower relay K-09 C5 open C6 open C7 904 (WH) Output to main blower relay low K-11 C8 905 (WH) Output to main blower relay med K-12 C9 906 (WH) Output to main blower relay high K-13 C10 907 (BL) Reference ground for A/C low pressure S-48 and freeze switch S-76 C11 908 (YE) Signal from A/C low pressure S-48 and freeze switch S-76 C12 909 (BL) To ATC control module A-15 C13 910 (YE) Not used C14 911 (BL) To ATC control module A-15 C15 912 (YE) To ATC control module A-15 C16 913 (BL) Reference ground for cab temp sensor B-26, evaporator temp sensor B-28 and A/C low pressure S-77 (ATC) D1 914 (YE) To ATC control module A-15 D2 939 (YE) Not used D3 934 (BL) Reference ground for A/C high pressure S-47 D4 917 (YE) Signal from A/C high pressure S-47 D5 918 (BK) To ATC control module A-15 D6 919 (YE) To ATC control module A-15