DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Hydraulic Systems pressure port. When the engine is at high idle and the swash plate is at its maximum angle the pump output is approximately 152 l/m (40 GPM). PFC Pump Operation The PFC pump assembly is located directly in front of the reservoir. The PFC pump is an axial-piston type pump. When the drive shaft of the piston pump is rotated, the piston cylinder block, which is splined to the drive shaft, also turns. The piston block contains nine piston assemblies which have free swiveling slippers attached to the ball-end of the piston assembly. The slippers ride against the machined surface of the swash plate. NOTE:
The pump is always engaged by the swash plate spring to its maximum output. The compensa- tor is always reducing the pumps output. Pump Compensator The pump compensator assembly controls the angle of the swash plate by directing oil to the swash plate control piston. The swash plate control piston will over come the swash plate control spring, placing the swash plate at the proper angle. When the swash plate is tilted from neutral to its maximum angle by the swash plate control spring, the piston slippers follow the inclined surface of the swash plate and begin moving in and out of the piston block bore.
Half of the piston assemblies are being pulled out of the piston block while the remaining half of the pistons are being pushed back into the piston block. As the pistons are pulled from the piston block, they draw oil into the piston block bores. This supply oil comes from the kidney shaped intake port. As the piston crosses over top dead center, the piston push the oil out of the piston block bores into a kidney shaped outlet pressure port. Each of the nine pistons completes this cycle for each revolution of the pump shaft. This causes a continuous even flow of oil from the pump. The main valve assembly, feeder valve assembly and steering hand pump each contain a signal port.
The signal port and associated lines direct a signal pressure to the pump compensator. This signal pressure is equal to the system work pressure. The pump compensator will use this signal to place the piston pump swash plate at the proper angle to meet the system demand. The outlet pressure at the pump will be 27.6 bar (400 psi) higher than the signal line pressure due to the 27.6 bar (400 psi) spring in the compensator. The pump outlet pressure will continue to be 27.6 bar (400 psi) higher than signal line pressure until the high-pressure standby pressure is reached. After high pressure standby is reached, the pump outlet pressure and the signal line pressure will become equal.
The greater the swash plate angle, the greater the piston stroke. This increase in stroke causes more oil to be pulled into the pump and discharged out of the A.10.A / 22