DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Hydraulic Systems de-stroking the pump. In this condition, the pump will only move enough oil to make up for internal leakage within the system and maintain 31--41.5 bar (450--600 psi). The pump will remain in this position until there is a demand for oil. In low-pressure standby mode the pump produces less heat and uses less horsepower than an open-center system. Low pressure standby also makes starting the engine easier. Low Pressure Standby When there is no demand for oil flow, the pump will go into the low-pressure standby mode. Low-pres- sure standby means low pressure and minimal flow in the system.
When the engine is not running, no pressure exists in any circuit. In this state, the swash plate control spring is holding the piston pump at full stroke. When the engine is started and the pump begins to rotate, it will momentarily try to pump oil. This creates outlet pressure at the pump. This pressure is directed to the flow compensator spool and the high-pressure spool through passages in the piston pump back plate. The two spools in the pump compensator are both spring biased. The flow compensator spool has a 27.6 bar (400 psi) spring while the high-pressure spool has a 186.3 bar (3050 psi) spring. The pump pressure is directed to the non-spring side of these two spools.
As pressure builds, it will cause the flow compensator spool to shift against its 27.6 bar (400 psi) spring. When the spool shifts it allows pump oil to pass to the pump control piston. This piston will extend and cause the swash plate to move against the control spring. The swash plate will move to a nearly zero degree angle, Minimum system pressure is 31--41.5 bar (450--600 psi) in the low-pressure standby mode. There is a 0.61 mm (0.024in) dynamic sensor orifice located in the steering priority spool. The dynamic sensor orifice connects the pump outlet port to the signal port of the pump compensator through the orifice check valve.
If the oil in the signal line can flow through the steering hand pump too freely a 0.78 mm (0.031 ) orifice in the steering hand pump signal passage provides back pressure in the signal line. This signal pressure of 3.45--10.3 bar (50--150 psi) is sent to the spring-end of the flow compensator spool. The spring pressure of 27.6 bar (400 psi) plus the signal line back pressure puts the pump into low pressure standby mode ranging from 31--41.5 bar (450--600 psi). 1. Signal Line-In 2. Flow Control Spool 3. High Pressure Spool 4. To Control Piston 5. Drain to Tank 6. Pump Output A. Low Pressure Standby Oil B. Drain Oil C. Trapped Oil A.10.A / 24