DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Hydraulic Systems provide more oil flow. When the flow demand of the system is met, the swash plate will be tilted to provide only the flow required by the component(s) in use. The working pressure in the system is fed back to the spring-end of the flow compensator spool through the signal line. The pump must produce flow at a pressure equal to the working pressure desired, plus enough to overcome the 27.6 bar (400 psi) spring on the flow compensator spool.
When the outlet pressure is high enough to overcome both the spring and work pressure, the flow compensator spool will shift allowing oil to flow to the control piston, causing the pump to destroke to match the demand. Pressure and Flow Compensation The flow of oil from the pump is controlled by the difference in pressure at opposite ends of the flow compensator spool. When a valve is opened to operate a function on the combine, the outlet pressure of the pump will drop. This drop in pressure is detected on the non-spring end of the flow compensator spool. The spring will now shift the spool and allow oil to drain from the pump control piston into the pump case.
The swash plate control spring will tilt the swash plate, causing the pump to 1. Signal Line-In 2. Flow Control Spool 3. High Pressure Spool 4. To Control Piston 5. Drain to Tank 6. Pump Output A. Pressurized Oil B. Drain Oil A.10.A / 26