DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Beacon Relay - Unidentified failure (A.40.A.15.82 - G.30.B.46) AFX8010 E0200-11 - Beacon Light Cause: The beacon lights relay K-29 circuit is open or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Relay failed. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" menu. Select the "LIGHTS" sort menu, and select "BEACON LT". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A.
If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with step 7 . 2. Turn the key switch "OFF". Remove the beacon lights relay K-29 from the fuse/relay panel, and use a multimeter to check the resistance of the relay coil. The proper resistance range for the relay coil is 74 - 78 ohms . A. If the resistance is out of specification, replace the relay. B. If the resistance is within specifications, continue with step 3 . 3. Use a multimeter to check for continuity between the relay socket pin 1 on the fuse/relay panel and chassis ground.
There should not be continuity to ground. A. If there is continuity to ground, there is a short to ground on the cab main (CM) harness between the fuse/relay panel and connector X015 pin J1-24 wire 182 white. Locate the short and repair. B. If there is no continuity to ground, continue with step 4 . 4. Use a multimeter to check for continuity between the relay socket pin 2 on the fuse/relay panel and chassis ground. There should be continuity to ground. A. If there is no continuity to ground, there is an open circuit in the cab main (CM) harness between the fuse/relay panel and cab ground 3 wire 160 black. Locate the open and repair. B.
If there is continuity to ground, continue with step 5 . 5. Turn the key switch to the "ON" position. Enter the Universal Display Plus "DIAG" menu. Select the "LIGHTS" sort menu, and select "BEACON LT". Press the "OFF" button to change the circuit output to "ON". Use a multimeter to check for 12 volts between the relay socket pin 1 on the fuse/relay panel and chassis ground. There should be 12 volts . A. If 12 volts is not present, continue with step 6 . B. If 12 volts is present, continue with step 7 . 6. Turn the key switch to the "ON" position. Enter the Universal Display Plus "DIAG" menu. Select the "LIGHTS" sort menu, and select "BEACON LT".
Press the "OFF" button to change the circuit output to "ON". Use a multimeter to check for 12 volts between connector X015 pin J1-24 and chassis ground. There should be 12 volts . A. If 12 volts is not present, the CCM2 controller is not functioning properly.Reload the software in CCM2 using the EST, and recheck the circuit operation. If the CCM2 module is still not providing 12 volts output, replace the module. 9668 1 27/05/2004 A.40.A / 53