Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM CONTROL PRESSURE SYSTEM On the AFX combines there are three individual hydrostatic drives, they all share common compo- nents. In the past we were accustomed to having a charge pump and filtering system for each hydrostatic drive, this system will use a common charge pump and filter for all drives. We would normally have call this the CHARGE pump and filter for the hydrostatic drive, it is now the CONTROL PRESSURE circuit. so on the AFX combine. Since the control pump will be supplying all three hydrostatic drives a larger pump is required. The control pump is the largest gear pump section of the gear pump assembly.

The customary charge pump that is incorporated into the ground drive hydrostatic pump assembly will be used ONLY for PTO gearbox cooling lubrication. NOTE: The Charge pressure is identified as “Control Pressure.” Normally the hydrostatic drive charge pump is mounted inside the hydrostatic pump end cover, not A.10.A / 42