Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Sensing system Moisture sensor - Electrical adjust (A.50.A.96.95.80 - F.45.A.61) AFX8010 1. The moisture sensor measures grain that is falling out of the clean grain elevator into a small bin of the by-pass unit. The moisture sensor is at the back of the by-pass unit and senses the moisture content of the grain in this bin. A proximity switch controls the level of grain in the bin. It is located at the top of the bin and an auger is at the bottom of the bin. In order to have a good moisture reading, the moisture sensor fin must always be clean and totally covered by grain.

In other words, the bin always has to contain a certain minimum amount of grain. The sensitivity of the proximity switch can be adjusted. If the level sensor is set too sensitive, the auger will start turning too early and not enough grain will be available in the sensor chamber to have a good moisture reading. As a result, you will see the moisture value on the Universal Display Plus fluctuating a lot and suddenly drop to a low level. If the level sensor is not set sensitive enough, the bin will always contain the same grain, resulting in a nearly constant moisture reading all over the field. 10037329 1 2. NOTE:

It should be noted that, although the level sensor sensitivity may be set correctly, it is possible that material blockage (i.e., pieces of corn cobs) in front of the level sensor will also cause the auger to turn continuously when the threshing system is on. This situation can be recognized when the moisture readings are abnormally low or fluctuating greatly. Therefore, before changing the sensitivity of the level sensor, remove the moisture sensor. Then you can look into the bin. In the top of the bin, a white circle (level sensor head surface) must be visible without being covered by dirt or crop residues. If you found material accumulated in front of the level sensor, remove it.

If the moisture reading is still fluctuating or the electrical motor keeps on turning all the time, then it is advised to change the sensitivity of the level sensor. 10037330 2 3. To set the sensitivity of the level sensor, proceed as follows: IMPORTANT: Before setting the sensitivity, check first that the moisture sensor fin and the level sensor are clean. Refer to Operator’s Manual, Section 4 – “Grain Storage - Moisture Sensor.” 9669 1 27/05/2004 A.50.A / 7