Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module - Overview (A.50.A.91 - C.10.A.10) 10004693A5 1 Chassis Control Modules (under Instructional seat in cab) 1. CCM1 2. CCM2 3. CCM3 4. Cab main (CM) harness connector X018 to CCM1 5. Cab main (CM) harness connector X015 to CCM2 6. Cab main (CM) harness connector X012 to CCM3 The chassis control modules (CCM’s) are the primary modules that control many of the functions on the combine. The modules are located inside the cab, under the instructional seat, and are bolted to the cab floor over access holes for electrical connectors. Each module has three electrical connectors attached to it.

The cab main (CM) harness attaches to each module from inside the cab, while the main frame (MF), front frame (FF), and expansion (EX) harnesses attach to the modules from outside the cab, through the holes in the cab floor. In general, the modules take care of the following functional areas of the combine: CCM1 module manages feeder engagement, header height control, cleaning system self-leveling, and concave adjustment. The main frame (MF) harness attaches to CCM1 connector X019 , while the front frame (FF) harness attaches to CCM1 connector X020 .

CCM2 module manages threshing system engagement, ground drive systems including transmission shifting, reel and unload tube hydraulics, and engine sensors monitoring. The main frame (MF) harness attaches to CCM2 connector X016 , while the front frame (FF) harness attaches to CCM2 connector X017 . CCM3 module manages rotor drive engagement, optional remote sieve adjustment, and some precision farming system operations. The expansion (EX) harness attaches to the CCM3 connectors X013 and X014 . 9669 1 27/05/2004 A.50.A / 12