DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM1 - Short circuit to ground (A.50.A.91.81 - G.30.B.53) AFX8010 E0038-04 - CCM1 8V Reference Cause: The CCM1 8V Reference circuit is shorted to ground. Possible failure modes: 1. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM1 8V REF" to check the voltage range. The proper voltage is 7.5 - 8.5 volts . A. If the voltage reading is low ( 7.5 volts ) out of range, then the CCM1 module has an internal failure. Replace the module. B.
If the voltage reading is within the proper limits, the failure may not be present at this time. Continue with step 2 . NOTE: Visually inspect the wiring harness and connectors to CCM1 module. Verify that the connectors are fully installed. Inspect the terminals and wires at the connectors for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Operate the machine while monitoring the Universal Display Plus "DIAG" screen, "CCM1 8V REF" voltage range. A. If no low ( 7.5 volts ) out of range readings are indicated, erase the fault code and continue operation.
Control module - Overview (A.50.A.91 - C.10.A.10) 10004693A5 1 Chassis Control Modules (under Instructional seat in cab) 1. CCM1 2. CCM2 3. CCM3 4. Cab main (CM) harness connector X018 to CCM1 5. Cab main (CM) harness connector X015 to CCM2 6. Cab main (CM) harness connector X012 to CCM3 The chassis control modules (CCM’s) are the primary modules that control many of the functions on the combine. The modules are located inside the cab, under the instructional seat, and are bolted to the cab floor over access holes for electrical connectors. Each module has three electrical connectors attached to it. The cab main (CM) 9669 1 27/05/2004 A.50.A / 15