DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM2 - Short circuit to B+ (A.50.A.91.82 - G.30.B.54) AFX8010 E0166-03 - CCM2 8V Reference Cause: The CCM2 8V Reference circuit is shorted to a higher than normal source. Possible failure modes: 1. 12 volts short on the 8 volts regulated power circuit. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM2 8V REF" to check the voltage range. The proper voltage is 7.5 - 8.5 volts . A. If the reading is high (> 8.5 volts ) out of range, continue with step 2 . B.
If the reading is within the proper range, reload the software in CCM2. Erase the fault code and continue operation. If the fault code persists, replace the module. NOTE: The 8 volts regulated power supply is provided from the key switch power to the module, and is used to provide power to speed and position sensor circuits. In some cases, a 12 volts short on one of the sensor signal wires could result in backfeeding that upsets the 8 volts regulator, and may cause the short to high source fault. 2. Turn off the key switch, and disconnect the negative battery cables to remove all power from the CCM2 module.
Carefully remove connector X016 and connector X017 from the bottom of the CCM2 module. Reconnect the negative battery cables, and turn the key on. Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM2 8V REF" to check the voltage range. The proper voltage is 7.5 - 8.5 volts . A. If the voltage reading is within the proper range, there is a short to high source on one of the sensor wires. Continue with step 3 . B. If the voltage reading is still high (> 8.5 volts ) out of range, then there is an internal failure in the CCM2 module. Replace the module. 3.
Turn off the key switch, and disconnect the negative battery cables to remove all power from the CCM2 module. Carefully reconnect connector X016 and connector X017 to the bottom of the CCM2 module. Reconnect the negative battery cables, and turn the key on. Enter the Universal Display Plus "ERROR" screen to check for any errors for sensor circuits short to high source on the CCM2 module. A. If there are any sensor circuits on CCM2 that are shorted to high source, correct those circuits, and then continue with step 1 of this troubleshooting to verify that this concern is resolved. B. If there are no sensor circuit errors on CCM2 module, reload the software in CCM2.
Erase the fault code and continue operation. If the fault code persists, replace the module. 9669 1 27/05/2004 A.50.A / 19