Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM1 - Short circuit to B+ (A.50.A.91.81 - G.30.B.54) AFX8010 E0037-03 - CCM1 J2 5V Reference Cause: The CCM1 J2 5 volts reference circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Circuit wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM1 J2 5V REF" to check the voltage range. The proper voltage range is 4.5 - 5.5 volts A. If the voltage reading is high out of range, continue with Step 2 . B.

If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 4 . 2. Disconnect the concave (CC) harness from the main frame (MF) harness at connector X456 . A. If the voltage drops back to the normal range, the short is in the concave (CC) harness, concave position sensor R-06, or sensor wiring. Inspect the concave (CC) harness for shorts, and replace the concave position sensor if necessary. B. If the voltage remains high, continue with Step 3 . 3. Disconnect the lateral inclination sensor connector X170 . A.

If the voltage drops back to the normal range, the short is in the lateral inclination sensor B-02, or sensor wiring. Replace the sensor. B. If the voltage remains high, continue with Step 4 . 4. Disconnect the feeder angle sensor connector X174 . A. If the voltage drops back to the normal range, the short is in the feeder angle sensor R-03, or sensor wiring. Replace the sensor. B. If the voltage remains high, continue with Step 5 . 5. Disconnect the header lift pressure sensor connector X279 . A. If the voltage drops back to the normal range, the short is in the header lift pressure sensor B-29, or sensor wiring. Replace the sensor. B. If the voltage remains high, continue with Step . 6.

Disconnect the PTO box lube pressure sensor connector X399 . A. If the voltage drops back to the normal range, the short is in the PTO box lube pressure sensor B-60, or sensor wiring. Replace the sensor. B. If the voltage remains high, there is a short to high voltage in the main frame (MF) harness between connector X456 pin 3, connector X170 pin A (B-02), connector X174 pin 3 (R-03), connector X279 pin B (B-29), connector X399 pin B (B-60) and connector X019 pin J2-31 on one of the following wires:

- wire 498 pink, connector X456 pin 3 to MF harness splice - wire 451 pink, connector X170 pin A to MF harness splice - wire 751 pink, connector X174 pin 3 to MF harness splice 9669 1 27/05/2004 A.50.A / 35