Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM1 - Short circuit to ground (A.50.A.91.81 - G.30.B.53) AFX8010 E0039-04 - CCM1 J3 5V Reference Cause: The CCM1 J3 5 volts reference circuit is shorted to ground. Possible failure modes: 1. Circuit wiring shorted to ground. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM1 J3 5V REF" to check the voltage range. The proper voltage range is 4.5 - 5.5 volts A. If the voltage reading is low (less than 4.5 volts ), continue with Step 2 . 2.

Disconnect the lower frame (LF) harness from the front frame (FF) harness at connector X023 . B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 4 . A. If the voltage increases to 4.5 - 5.5 volts , the short is in the lower frame (LF) harness between connector X023 and the shoe leveling actuator (M-03) connector X088 . Locate the short and repair. B. If the voltage remains low, continue with Step 3 . 3. Disconnect the feeder (FE) harness from the front frame (FF) harness at connector X007 . A.

If the voltage increases to 4.5 - 5.5 volts , the short is in the feeder (FE) harness between connector X007 and the header tilt potentiometer (R02) connector X081 . Locate the short and repair. B. If the voltage remains low, the short circuit is in the front frame (FF) harness between connectors X023 , X007 and connector X020 J3-26 wires 726 pink, 727 pink or 757 pink. Locate the short and repair. 4. Visually inspect harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase fault code and continue operation. Wiring harness - Electrical schematic frame 13 (A.30.A.88 - C.20.E.13) 9669 1 27/05/2004 A.50.A / 55