DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM2 - Short circuit to B+ (A.50.A.91.82 - G.30.B.54) AFX8010 E0167-03 - CCM2 J3 5V Reference Context: The CCM2 J3 5V Reference circuit supplies power from connector X017 pin J3-26 to the header type module R-20 in the header (HH) harness. A short to high voltage on this supply wire will result in this fault code being displayed. Cause: The CCM2 J3 5V Reference circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen.
Select the "VOLTAGE" sort menu, and select "CCM3 J3 5V REF" to check the voltage range. The proper voltage supply is 4.5 - 5.5 volts . A. If the voltage reading is high out of range (> 5.5 volts ), continue with Step 2 . B. If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 4 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2.
Disconnect the header type module connector X435. A. If the voltage decreases to 4.5 - 5.5 volts , the short is in the sensor. Replace the sensor. B. If the voltage remains high, continue with Step 3 . 3. Disconnect the header (HH) harness from the feeder (FE) harness at connector X032 . A. If the voltage decreases to 4.5 - 5.5 volts , there is a short circuit in the header (HH) harness between connector X435 and connector X032 wire 1223 pink. Locate the short and repair. B. If the voltage remains high, continue with Step 4 . 4. Disconnect the feeder (FE) harness from the front frame (FF) harness at connector X007 . A.
If the voltage decreases to 4.5 - 5.5 volts , there is a short circuit in the feeder (FE) harness between connector X007 and connector X032 wire 1223 pink. Locate the short and repair. B. If the voltage remains high, continue with Step 3 . 5. Carefully disconnect connector X017 from the bottom of the CCM2 module. Use a multimeter to check for voltage at connector X017 pin J3-26. There should be 4.5 - 5.5 volts . A. If the voltage is within 4.5 - 5.5 volts , there is a short in the front frame (FF) harness between connector X017 and connector X007 wire 1223 pink. Locate the short and repair. B.
If the voltage is greater than 5.5 volts , there is a problem with an internal component in the CCM2 module. Replace the module. 6. Operate the machine while monitoring the Universal Display Plus "DIAG" screen. A. If no high out of range readings are indicated, erase the fault code and continue operation. 9669 1 27/05/2004 A.50.A / 63