DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM2 - Short circuit to ground (A.50.A.91.82 - G.30.B.53) AFX8010 E0167-04 - CCM2 J3 5V Reference Context: The CCM2 J3 5V Reference circuit supplies power from connector X017 pin J3-26 to the header type module R-20 in the header (HH) harness. A short to ground on this supply wire will result in this fault code being displayed. Cause: The CCM2 J3 5V Reference circuit is shorted to ground. Possible failure modes: 1. Sensor supply wiring shorted to ground. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen.
Select the "VOLTAGE" sort menu, and select "CCM3 J3 5V REF" to check the voltage range. The proper voltage supply is 4.5 - 5.5 volts . A. If the voltage reading is low out of range ( 4.5 volts ), continue with Step 2 . B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 4 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the header type module connector X435. A.
If the voltage increases to 4.5 - 5.5 volts , the short is in the sensor. Replace the sensor. B. If the voltage remains low, continue with Step 3 . 3. Disconnect the header (HH) harness from the feeder (FE) harness at connector X032 . A. If the voltage increases to 4.5 - 5.5 volts , there is a short to ground in the header (HH) harness between connector X435 and connector X032 wire 1223 pink. Locate the short and repair. 4. Disconnect the feeder (FE) harness from the front frame (FF) harness at connector X007 . B. If the voltage remains low, continue with Step 4 . A.
If the voltage increases to 4.5 - 5.5 volts , there is a short to ground in the feeder (FE) harness between connector X007 and connector X032 wire 1223 pink. Locate the short and repair. B. If the voltage remains low, continue with Step 3 . 5. Carefully disconnect connector X017 from the bottom of the CCM2 module. Use a multimeter to check for voltage at connector X017 pin J3-26. There should be 4.5 - 5.5 volts . A. If the voltage is within 4.5 - 5.5 volts , there is a short to ground in the front frame (FF) harness between connector X017 and connector X007 wire 1223 pink. Locate the short and repair. B.
If the voltage is less than 4.5 volts , there is a problem with an internal component in the CCM2 module. Replace the module. 6. Operate the machine while monitoring the Universal Display Plus "DIAG" screen. A. If no low out of range readings are indicated, erase the fault code and continue operation. 9669 1 27/05/2004 A.50.A / 67