Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM2 - Short circuit to B+ (A.50.A.91.82 - G.30.B.54) AFX8010 E0174-03 - CCM2 Battery Voltage Cause: The CCM2 battery power supply circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Circuit wiring shorted to high voltage source. 2. Faulty alternator/regulator. 3. Controller internal failure (internal regulator failure). Solution: 1. Start the combine engine . Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM2 BAT" to check the voltage range. Increase the engine RPM to high idle (maximum) and check voltage range.

The acceptable voltage range for the module is 10 - 18 volts . A. If the voltage reading is greater than 18 volts , continue with Step 2 . B. If the voltage reading is between 10 - 18 volts , continue with step 5 . 2. Shut off the combine engine . Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM2 BAT" to check the voltage range. The acceptable voltage range for the module is 10 - 18 volts . A. If the voltage reading is between 10 - 18 volts , the alternator and/or regulator has failed, and is producing excessive voltage. Refer to Alternator - Problem solving (A.30.A.82 - G.40.A.30) for additional alternator testing information. B.

If the voltage reading is greater than 18 volts , continue with step 3 . 3. Turn off the key switch to power down the system. Use a multimeter to check the voltage at fuse F-39. A. If the voltage reading is greater than 18 volts , then there is a fault in the wiring of the 24V starting system. Refer to STARTING SYSTEM - Problem solving (B.80.A - G.40.A.30) for additional information. B. If the voltage reading is between 10 - 18 volts , continue with step 4 . 4. Remove the instructional seat and storage bin to gain access to the CCM2 connector X015 . Turn the key switch ON. Use a multimeter to check the voltage at connector X015 pin J1-1. A.

If the voltage reading is greater than 18 volts , then a high voltage source has been connected to one of the following wires in the cab main (CM) harness: - wire 047 red, fuse F39 to CM harness splice - wire 049 red, CM harness splice to CCM3 connector X012 pin J1-1 - wire 050 red, CM harness splice to CCM2 connector X015 pin J1-1 - wire 052 red, CM harness splice to CCM1 connector X018 pin J1-1 - wire 057 red, CM harness splice to display adapter (AD) harness connector X064 pin D - wire 051 red, CM harness splice through connector X001 to RHM connector X026 pin 13 - wire 142 red, CM harness splice to DAM connector X065 pin B Locate the source of high voltage and repair. B.

If the voltage reading is 10 - 18 volts , and the diagnostic screen is still indicating voltage in excess of 18 volts , there is an internal fault in CCM2.Reload the software for CCM2. If that does not correct the concern, replace the module. 5. Operate the combine while monitoring the voltage on the Universal Display Plus "DIAG" screen. 9669 1 27/05/2004 A.50.A / 89