Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM Control module CCM3 - Short circuit to B+ (A.50.A.91.83 - G.30.B.54) AFX8010 E0293-03 - CCM3 J2 5V Reference Context: The CCM3 J2 5V Reference circuit supplies power from connector X013 pin J2-31 to the upper sieve actuator M-06 and lower sieve actuator M-07 for the internal position sensors. A short to high voltage on these supply wires will result in this fault code being displayed. Cause: The CCM3 J2 5V Reference circuit is shorted to a higher than normal source. Possible failure modes: 1. CCM3 J2 5V Reference wiring shorted to a higher than normal source. 2. Controller internal failure (internal regulator failure). Solution: 1.

Enter the Universal Display Plus "DIAG" screen. Select the "VOLTAGE" sort menu, and select "CCM3 J2 5V REF" to check the voltage range. The proper voltage is 4.5 - 5.5 volts . A. If the voltage reading is high, out of range (> 5.5 volts ), continue with Step 2 . B. If the voltage reading is within proper limits, the shorted wire may not be powered up at this time. Continue troubleshooting with Step 4 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.

Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the straw hood front (SW) harness from the lower frame rear (LR) harness at connector X072 . A. If the voltage drops to the normal range, there is a short to high voltage in the lower frame rear (LR) harness between connector X072 pin E and connector X227 pin A wire 793 pink, or between connector X072 pin K and connector X228 pin A wire 794 pink. Locate the short and repair. B. If the voltage remains high, continue with Step 3 . 3. Disconnect the main frame (MF) harness from the straw hood front (SW) harness at connector X025 . A.

If the voltage drops to the normal range, there is a short to high voltage in the straw hood front (SW) harness between connector X025 pin 1 and connector X072 pins E & K on one of the following wires: - wire 683 pink, connector X025 pin 1 to SW harness splice - wire 793 pink, SW harness splice to connector X072 pin E - wire 794 pink, SW harness splice to connector X072 pin K. Locate the short and repair. B. If the voltage remains high, there is a short in the expansion (EX) harness between connector X025 pin 1 and connector X013 pin J2-31 wire 683 pink, 1253 pink or 1196 pink. Locate the short and repair. 4. Operate the machine while monitoring the Universal Display Plus "DIAG" screen.

Operate the remote sieves to determine if the fault occurs while the sieve actuators are operating. A. If no high out of range readings are indicated, erase the fault code and continue operation. 9669 1 27/05/2004 A.50.A / 93