Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM # 2 High Pressure Standby This test is used to determine the spring setting of the high-pressure spool in the compensator. High-pres- sure standby is the maximum pressure that the PFC pump will develop. High pressure stand-by on is 207--214 bar (3000--3100 PSI). There is no relief valve in the PFC circuit so the high-pressure standby limit serves as the system relief. from the feeder house if a grain header is attached. With the engine at high idle, activate the reel raise circuit. The gauge should read between 207--214 bar (3000--3100 PSI). If adjustment is required remove the cap for the adjustment screw located on the compensator.

Use an allen wrench to adjust the spring setting. After the adjustment has been made, the test should be repeated to verify the spring setting. Test Procedure Attach a 345 bar (5000 psi) gauge to the PFC pump pressure test port (13). Disconnect the reel lift hose A.10.A / 64