Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM # 3 Steering Relief Setting This test is used to determine the relief valve setting of the steering signal circuit. The steering signal relief valve is set to provide an operating pressure of 182.7--189.6 bar (2650--2750 psi). If the steering signal is too high the steering circuit can limit or completely stop the oil flow to the other hydraulic functions. steering hand pump must be removed from the combine. The relief valve adjustment is an allen plug located on the mounting surface of the hand pump. The plug will be filled with wax.

After removing the wax, turn the threaded plug in to increase the relief valve setting, and out to decrease the setting. After the adjustment has been made, the test should be repeated to verify the spring setting. Before installing the hand pump in the combine, replace the wax with LOCTITE to prevent the adjusting plug from moving. Test Procedure Attach a 345 bar (5000 psi) gauge to the pump pressure DIAG port located on the Main Valve Stack. With the engine at low idle, turn the steering wheel until the steering stops are reached and hold the wheel. The relief valve in the steering hand pump will open. The reading on the gauge should be between 182.7--189.6 bar (2650--2750 psi). NOTE:

Steering from full RIGHT to full LEFT should take approximately 4.5 turns. If the steering system requires more turns, it could be a sign of a hand pump that has too much internal leakage or a steering cylinder with internal leakage. When holding the steering wheel against the stop, continue to apply normal steering pressure on the wheel, there should not be more then approx. 1.5 wheel rotation per minute due to internal leakage. The relief is located in the steering hand pump and is set from the factory. If adjustment is needed, the A.10.A / 66