Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM # 4 Bench Testing Components that the pressure will act on the end of the relief valve. Create enough pressure to open the relief valve. The reading on the gauge should read 210 bar (3000 psi). If adjustment is required, remove the cap on the relief valve and loosen the jam nut. Use an allen wrench to adjust the screw. Turn the screw in to increase the relief pressure setting, or turn the screw out to decrease the relief pressure setting. After the adjustment has been made the test should be repeated to verify the relief valve setting.

Field Tracker, Spreader Relief and Feeder Thermal Relief Valves This test is used to determine the pressure settings of the relief valves when the system can not be loaded to relief valve settings. Test Procedure To bench test relief valves use special tool CAS--1905--2, CAS--1905--3 and adapter 1252331C1. A hydraulic hand pump or tractor remote valve can be used to supply pressure to the test block 206934. Fan Drive Relief Valve To test the fan drive relief valve, thread it into the test block and attach the supply hose to the test block so that the pressure will act on the end of the relief valve. Create enough pressure to open the relief valve.

The reading on the gauge should read 241 bar (3500 psi). If adjustment is required, remove the cap on the relief valve and loosen the jam nut. Use an allen wrench to adjust the screw. Turn the screw in to increase the relief pressure setting, or turn the screw out to decrease the relief pressure setting. After the adjustment has been made the test should be repeated to verify the relief valve setting. Terrain Tracker Relief Valve To test the terrain tracker relief valves, thread it in to the test block and attach the supply hose to the test block so that the pressure will act on the side of the relief valve. Create enough pressure to open the relief valve.

The reading on the gauge should read 207 bar (3000 psi). If adjustment is required, remove the cap and use an allen wrench to turn the threaded plug. Turn the plug in to increase the relief pressure setting, or turn the plug out to decrease the relief pressure setting. After the adjustment has been made, the test should be repeated to verify the relief valve setting. Feeder Lift Cylinder Thermal Relief Valve To test the feeder thermal relief valve, thread it into the test block and attach the supply hose to the test block so that the pressure will act on the end of the relief valve. Create enough pressure to open the relief valve. The reading on the gauge should read 276 bar (4000 psi) .

If the valve drips before it opens at the set pressure the header will settle. Spreader Relief Valve To test the spreader relief valve, thread it into the test block and attach the supply hose to the test block so A.10.A / 68