Case IH AFX8010 — FUEL AND INJECTION SYSTEM

POWER PRODUCTION - FUEL AND INJECTION SYSTEM Injection control - Incorrect value (B.20.A.92 - G.30.C.10) AFX8010 E0394-02 - Afterrun Not Completed Cause: Afterrun monitoring not completed Possible failure modes: Effect on Engine: Engine enabled -- no restriction on fuel or speed 1. Faulty Main Relay (K14) 2. Low battery voltage Solution: 1. Check fuses F-01 and F-38. A. Replace fuse if blown. Remove the fault code from the engine ECU memory using the electronic service tool and check the operation of the engine. If fuse blows again,inspect wiring harness for damage. B. If fuses are okay, continue with step 2 . 2. Check battery voltage. A.

If voltage is less than 9.5 Volts, check the battery and charging system. Ensure the battery has the correct voltage and remove the fault code from the engine ECU memory using the electronic service tool. Operate the engine, if the fault reoccurs continue with step 3 . B. If the voltage is greater than 9.5 Volts, continue with step 3 . 3. Check the Main Relay (K-14). A. Remove the relay and check its operation. If okay, continue with step 4 . B. Replace the relay if faulty. Remove the fault code from the engine ECU memory using the electronic service tool. Operate the engine, if the fault reoccurs, continue with step 4 . 4. Check the wiring harness. A.

Remove relay 14 and check for continuity of the wiring between the engine ECU connector X193 and the relay 14 holder. Check between pin 2 of the holder and pin 27 of X193 and between pin 5 of the holder and pins 3 and 4 of X193 . If an open circuit is indicated at any stage repair or replace the wiring as required. B. If continuity is good remove the fault code from the ECU memory, using the electronic service tool and operate the engine. The fault may be intermittent, wiggle test the harness to attempt to induce the fault. If fault reoccurs repeat step 4. If fault does not occur continue with vehicle operation. 9672 1 27/05/2004 B.20.A / 59