Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM # 7 Regulated Pressure Test This test is used to determine the regulated pressure relief valve setting. The regulated pressure relief valve is set to provide an operating pressure of 22--25 bar (320--360 psi). Valve. With the engine at LOW idle the pressure reading should be within specification, check at HIGH idle to verify operation. The relief is located in the valve body. The cartridge is adjustable; if pressure is not correct make the required adjustment. Test Procedure Attach a 41 bar (600 psi) gauge to the regulated pressure DIAG port located on the Park Brake/Tow A.10.A / 74