POWER PRODUCTION - FUEL AND INJECTION SYSTEM Sensing system Level sensor - Short circuit to B+ (B.20.A.95.90 - G.30.B.54) AFX8010 E0154-03 - Fuel Level Sensor Cause: The fuel level sensor (R-01) circuit is shorted to 12 volts. Possible failure modes: 1. Sensor supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "ENGINE" sort menu, and select "FUEL LEVEL SEN" to check the voltage range. The proper voltage range is - 0.5 - 4.9 volts . A. If the voltage reading is high out of range, (> 5.2 volts ), continue with Step 2 . NOTE: Visually inspect the wiring harness and connectors.
Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 3 . 2. Disconnect the fuel level sensor connector X184 . A. If the voltage drops to 4.9 - 5.2 volts , the short is in the sensor or sensor wiring. Replace the sensor. B. If the voltage remains high, there is a short circuit in the main frame (MF) harness between connector X184 pin 1 and connector X016 pin J2-17 wire 427 yellow. Locate the short and repair. 3.
Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9672 1 27/05/2004 B.20.A / 80