DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM # 8 Spreader Pump Flow Test This test is used to determine the efficiency of the spreader pump. The pump will wear internally over time, causing the residue spreader speed to decrease. If Flow Is Below Specifications 1. There could be a problem with the flow control o-rings. 2. There could be a problem with the relief valve o-rings NOTE: Since all the flow from the spreader pump is directed through the rotary air screen motor a quick RPM check of the screen may be all that is required to determine the condition of the pump. The screen should turn a minimum of 205 RPM. Be sure to verify the condition of the spreader relief valve. 3.
There could be a problem with the control solenoid o-rings and spool. 4. The pump could be worn excessively. If the flow is below specifications the flow rater could be installed between the pump and the control valve. Test Procedure 1. Remove the supply hose that runs between the spreader valve and the left hand spreader motor. Connect the inlet hose from a flow rater to the spreader valve and the outlet hose from the flow rater back to the hydraulic reservoir tank. CAUTION Use extreme caution if this procedure is used. There is no relief valve in the system when testing in this manner. Be absolutely sure the flow meter restrictor is open when starting the combine engine.
Once the machine is started, increase to full throttle and VERY SLOWLY restrict the flowmeter NOT to exceed pressure specifications. 2. Turn the spreader valve flow control to the maximum flow setting. 3. Open the restriction valve on the flow rater completely. 4. Start the machine’s separator and run the engine at high idle. 5. The pump’s output should be above minimum specification. 6. Slowly turn in the flow raters restriction control to verify the systems relief valve, it should be above minimum system specification. 7. The pump flow at approximately 21 bar (300 psi) below the relief valve setting should still be above minimum specification. A.10.A / 76