Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM # 9 Fan Pump Flow Test This test is used to determine the efficiency of the fan drive pump. The pump will wear internally over time, causing the fan speed to decrease. If Flow Is Below Specifications 1. If equipped, use the manual speed control adjustment screw on the top of the control solenoid to override the electrical system. 2. There could be a problem with the relief valve o-rings. Test Procedure 1. Remove the supply hose that runs between the fan drive valve and the fan motor. Connect the inlet hose from a flow rater to the fan valve and the outlet hose from the flow rater back to the hydraulic reservoir tank. 3.

There could be a problem with the control solenoid o-rings and spool. 4. The pump could be worn excessively. 2. Open the restriction valve on the flow rater completely. If the flow is below specifications the flow rater could be installed between the pump and the control valve. 3. Start the machine’s separator, using the operator controls set the fan speed to the minimum setting and run the engine at high idle. CAUTION 4. While monitoring the fan pump’s output increase the fan speed, verifying the solenoid and software operation. The pump’s output should be above minimum specification. Use extreme caution if this procedure is used.

There is no relief valve in the system when testing in this manner. Be absolutely sure the flow meter restrictor is open when starting the combine engine. Once the machine is started, increase to full throttle and VERY SLOWLY restrict the flowmeter NOT to exceed pressure specifications. 5. Slowly turn in the flow raters restriction control to verify the systems relief valve, it should be above minimum system specification. 6. The pump flow at approximately 21 bar (300 psi) below the relief valve setting should still be above minimum specification. A.10.A / 78