POWER PRODUCTION - AIR INTAKE SYSTEM Sensing system Air temperature sensor - Short circuit to ground (B.30.A.95.80 - G.30.B.53) AFX8010 E0400-04 - Boost Air Temperature Cause: Signal range outside threshold limits Signal not plausible or intermittent fault Possible failure modes: Effect on Engine: Engine enabled - no restriction on fuel or speed 1. Faulty sensor 2. Faulty connector or wiring Solution: 1. Harness connector fault A. Inspect the harness connector X374 onto the air temp sensor B-54. Ensure that the connector is not damaged, the pins are correctly located in the connector body and that it is a tight fit onto the sensor. B. If the harness connector is okay, continue with step 3 .
2. Air Temp Sensor B54 Fault: To test the sensor measure the resistance across pins 1 and 2 of the sensor. The resistance will vary according to the temperature detailed in the table below: A. If the sensor resistance is incorrect, replace the sensor. B. If the sensor resistance is correct, continue with step 3 .
9673 1 27/05/2004 B.30.A / 37 Resistance in Ohms Ambient Air Minimum Nominal Maximum Temperature -40 °C (-40 °F) 38313 ohms 45313 ohms 53103 ohms -30 °C (-22 °F) 22362 ohms 26114 ohms 30258 ohms -20 °C (-4 °F) 13402 ohms 15462 ohms 17718 ohms -10 °C (14 °F) 8244 ohms 9397 ohms 10661 ohms 0 °C (32 °F) 5227 ohms 5896 ohms 6623 ohms 10 °C (50 °F) 3396 ohms 3792 ohms 4222 ohms 20 °C (68 °F) 2262 ohms 2500 ohms 2760 ohms 30 °C (86 °F) 1555 ohms 1707 ohms 1867 ohms 40 °C (104 °F) 1080 ohms 1175 ohms 1277 ohms 50 °C (122 °F) 771 ohms 834 ohms 900 ohms 60 °C (140 °F) 555 ohms 595 ohms 639 ohms 70 °C (158 °F) 408 ohms 435 ohms 465 ohms 80 °C (176 °F) 304 ohms 322 ohms 342 ohms 90 °C (194 °F) 231 ohms 243 ohms 257 ohms 100 °C (212 °F) 178 ohms 186 ohms 196 ohms 110 °C (230 °F) 137 ohms 144 ohms 152 ohms 120 °C (248 °F) 106 ohms 112 ohms 119 ohms 130 °C (266 °F) 84 ohms 89 ohms 95 ohms