heidenhain PWT 100, PWT 101 — Diagnostic values of the PWT display

8 Encoder diagnostics | Diagnosis for encoders with TTL/HTL/HTLs/ interface Zero crossovers of reference-mark signal In the bar graph of the reference-mark zero crossovers, the positions of two black bars show the deviation of the zero crossovers of the reference mark signal from the specified values. Figure 47: Bar graph of zero crossovers of reference-mark signal After a certain time interval (15 s) the display is deactivated (gray). As soon as the device detects the next reference mark, the display is reactivated. Resetting the drag indicators and warnings You can reset the drag indicators and warnings displayed in the PWT display screen.

Tap the Refresh button The displayed drag indicators and warnings are reset Diagnostic values of the PWT display Count value The Count value [steps] screen (4) shows count values, depending on the selection. If, in the Display settings screen, the option Rotatory or Linear is selected, the count value display is set to Abs . If, in the Display settings screen, the option Steps is selected, the count value display is set to Inc . Count value Yellow White Inc Reference mark(s) not yet detected or Off selected Reference mark(s) detected Abs Reference mark(s) not yet detected or Off selected Reference mark(s) detected Tapping the display opens the Display options for count value screen.

Further information: "Display options for count value screen ", Page 107 Reference mark RM (5) shows the status of reference-mark detection. The product uses the following colors for displaying the status: Color Status Description Green Reference mark detect- ed The display is activated for approx. 0.5 s. If the refer- ence marks follow in too quick a succession, the display may seem to be continuously active. Gray Reference mark not detected Reference mark not yet traversed or reference mark not detected If the reference mark is not detected correctly during signal evaluation, a signal evaluation warning is additionally displayed next to the RM.Pos. (reference mark position) and RM.ZC.

(reference-mark zero crossovers) bar graphs. HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2021 101