heidenhain PWT 100, PWT 101 — 8.4.8 Encoder status screen

8 Encoder diagnostics | Diagnosis for encoders with serial interface Classification of status messages The messages displayed by the product for the serial interface are classified as follows: Message Description Transmission errors Transmission errors indicate communication errors that may be caused by EMC influences, for example. Examples of transmission errors that may be displayed: Timeout CRC error Certain interfaces, such as EnDat, provide measures for protecting the transmission between the encoder and the subsequent electronics from transmission errors. Transmission can be protected by means of a CRC (cyclic redundancy check), for example.

Encoder errors Encoder errors indicate a malfunction of the encoder. Examples of encoder errors that may be displayed by encoders with EnDat interface: Bit 0 – Light source failure Bit 1 – Signal amplitude faulty Bit 2 – Position faulty Bit 3 – Overvoltage Bit 4 – Undervoltage supply The Group alarm message is displayed by encoders with Fanuc, Mitsubishi, Yaskawa or Panasonic interface without any detailed information If encoder errors are displayed, incorrect position values must be assumed. Operating condition error sources are displayed where appropriate. Operating condition error sources are extended encoder errors.

Encoder warnings Encoder warnings indicate that certain tolerance limits of the encoder have been reached or exceeded. Examples of encoder warnings that may be displayed by encoders with EnDat interface: Bit 1 – Temperature exceeded The Group warning message is displayed by encoders with Fanuc, Mitsubishi, Yaskawa or Panasonic interface without any detailed information The encoder warnings displayed do not state whether the measured position values are correct or incorrect. HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2021 71