heidenhain PWT 100, PWT 101 — 8.5.3 Encoder information screen

Encoder diagnostics | Diagnostics for encoders with 1 V PP /11 µA PP /1 V PP + Z1 interface 8 AB-CD deviation In the bar graph of the AB-CD deviation, the position of the black bar indicates the deviation of the calculated Z1-track position. The reference to the corresponding reference position is made on the basis of the C and D signals. The reference position is established from the incremental track, based on the A and B signals. The farther the black bar moves away from the center position, the larger the deviation from the reference position is. Figure 28: AB-CD deviation (distance between graduation lines:

1°, with one encoder revolution corresponding to 360°) 8.5.3 Encoder information screen Figure 29: Encoder information screen The Encoder information screen displays information saved about the connected encoder. Precondition: The encoder supports this function. The Encoder information screen displays only selected information on the connected encoder. This screen does not show the complete memory contents of the encoder. 80 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2021