SERIES 60 EGR TECHNICIAN'S GUIDE LOGIC CODES (MECHANICAL FAILURES) Logic codes indicate the detection of mechanical failures by the DDEC V system. The response will be a Flash Code. Diagnosing Flash Code 13 Failure Mode : SID 146, FMI 6 Indicates : EGR Valve Current is too high. Response : Perform the following steps if the EGR Valve current is too high. 1. Check for a short circuit. 2. Disconnect the harness connector from the actuator control valve coil. 3. Measure the coil resistance between pins A and B.Table 9-2 and see Figure 9-1. [a] If the coil resistance is to low replace the actuator assembly. [b] If the coil resistance is okay, go to step 4. 4.
Disconnect engine harness at ECU and at coil and measure resistance across the two pin connector pins. [a] If resistance is less than 100 , the two wires are shorted to each other. [b] If the resistance is greater than 100 , try a test ECU or contact Detroit Diesel Technical Service. Figure 9-1 EGR Valve Coil Wiring All information subject to change without notice. (Rev. April 2004) 9-9 7SE60 0404 Copyright © 2004 DETROIT DIESEL CORPORATION