SERIES 60 EGR TECHNICIAN'S GUIDE Turbo Speed Sensor Failure Modes : PID 103, FMI 8 - Abnormal Period Response : The CEL will be illuminated and the system will be forced into boost mode. The VNT vane position will be restricted so the vane will not close beyond a calibrated position. The engine will be torque limited during this fault. Ambient Air Temperature Sensor Failure Modes : PID 171, FMI 3 - Voltage High and FMI 4 - Voltage Low Response : The CEL will be illuminated and the temperature will be set to a calibrated value. Protection Codes Engine Protection Codes When these codes are logged and turn on both the check engine and stop engine lights.
This alerts the operator that continued engine operation under those conditions will result in engine damage. Coolant Temperature High PID 110 FMI 0 indicates the coolant temperature has risen above the programmed value in the ECM. The temperature limits are listed in Table 4-2. Oil Pressure Low PID 100 FMI 1 indicates that the oil pressure has dropped below a programmed value of 30 seconds. Both CEL and SEL will illuminate. The Series 60 pressure limit parameters and listed below. See Figure 4-1. Figure 4-1 Oil Pressure Shutdown All information subject to change without notice. (Rev. April 2004) 4-13 7SE60 0404 Copyright © 2004 DETROIT DIESEL CORPORATION