76 SEBU7901-01 Maintenance Section Engine Valve Rotators - Inspect i01597115 Engine Valve Rotators - Inspect SMCS Code: 1109-040 When inspecting the valve rotators, protective glasses or face shield and protective clothing must be worn, to help prevent being burned by hot oil or spray. Engine valve rotators rotate the valves when the engine runs. This helps to prevent deposits from building up on the valves and the valve seats. g00746166 Illustration 39 Typical location of the grease fitting (if equipped) that is for the fan drive bearing Perform the following steps after the engine valve lash is set, but before the valve covers are installed:
The pulley is shown with the belt guards that have been removed. 1. Start the engine according to Operation and Maintenance Manual, “Engine Starting” (Operation Section) for the procedure. Lubricate the grease fitting that is on the fan drive bearing with Bearing Lubricant or the equivalent. Inspect the fan drive pulley assembly for wear or for damage. If the shaft is loose, an inspection of the internal components should be performed. Refer to the Service Manual for additional information. 2. Operate the engine at low idle. 3. Observe the top surface of each valve rotator. The valve rotators should turn slightly when the valves close.
i02053753 Fan Drive Bearing - Replace NOTICE A valve rotator which does not operate properly will accelerate valve face wear and valve seat wear and shorten valve life. If a damaged rotator is not replaced, valve face guttering could result and cause pieces of the valve to fall into the cylinder. This can cause piston and cylinder head damage. SMCS Code: 1359-510-BD 1. Remove Bearings. Refer to Disassembly and Assembly, “Bearing Removal”. 2. Measure the bearing housings for roundness and for proper size. If a valve fails to rotate, consult your Caterpillar dealer. 3. Replace the bearings. i02239650 Fan Drive Bearing - Lubricate i02075183 Fuel System - Prime SMCS Code: 1258-548 SMCS Code:
1359-086-BD Some of the fan drives have grease fittings and some of the fan drives do not have grease fittings. If there is no grease fitting, periodic lubrication is not required. The fan drive requires grease only if the fan drive is equipped with a zerk. The Secondary Fuel Filter Has Been Replaced Fuel leaked or spilled onto hot surfaces or elec- trical components can cause a fire. To help pre- vent possible injury, turn the start switch off when changing fuel filters or water separator elements. Clean up fuel spills immediately.