Appendix A: USABC 12-V Stop/Start Battery Pack Goals SOC, state of charge.
223 End of Life Characteristics Units Target Under Hood Not Under Hood Discharge Pulse, 1 s kW 6 Max Discharge Current, 0.5 s A 900 Cold cranking power at −30 °C kW 6 KW for 0.5 s followed by 4 kW for 4 s (three 4.5-s pulses, 10 s rest between pulses at minimum SOC) Minimum voltage under cold crank Vdc 8.0 Available energy (750 W accessory load power) Wh 360 Peak recharge rate, 10 s kW 2.2 Sustained recharge rate W 750 Cycle life, every 10% life RPT with cold crank at Engine starts/ 450,000/150,000 minimum SOC miles Calendar life at 30 °C, 45 °C if under hood Years 15 at 45 °C 15 at 30 °C Minimum round trip energy efficiency % 95 Maximum allowable self-discharge rate Wh/day 2 Peak operating voltage, 10 s Vdc 15.0 Sustained operating voltage—maximum Vdc 14.6 Minimum operating voltage under autostart Vdc 10.5 Operating temperature range (available energy °C −30 °C to +75 °C −30 °C to +52 °C to allow 6-kW, 91-s pulse) 30 °C to 52 °C Wh 360 (to 75 °C) 360 0 °C Wh 180 −10 °C Wh 108 −20 °C Wh 54 −30 °C Wh 36 Survival temperature range °C −46 °C to −46 °C to +66 °C +100 °C Maximum system weight kg 10 Maximum system volume L 7 Maximum selling price (at 250,000 units/year) $ USD $220 $180