Kubota — GENERAL

05-E2B, 05-E2BG, WSM G GENERAL [4] CHECK POINTS OF EVERY 100 HOURS Cleaning Air Cleaner Element 1. Remove the air cleaner element. 2. Use clean dry compressed air on the inside of the element. Pressure of compressed air must be under 205 kPa (2.1 kgf/cm 2 , 30 psi). Maintain reasonable distance between the nozzle and the filter. NOTE Q The air cleaner uses a dry element. Never apply oil to it. Do not run the engine with filter element removed. Change the element once a year or every 6th cleaning. W1045746 Cleaning Fuel Filter (Element Type only) 1. Close the fuel cock (3). 2. Unscrew the retaining ring (6) and remove the filter cup (5), and rinse the inside with kerosene. 3.

Take out the element (4) and dip it in the kerosene to rinse. 4. After cleaning, reassemble the fuel filter, keeping out dust and dirt. 5. Bleed the fuel system. IMPORTANT Q If dust and dirt enter the fuel, the fuel injection pump and injection nozzle will wear quickly. To prevent this, be sure to clean the fuel filter cup (5) periodically. (1) Cock Body (2) Air Vent Plug (3) Fuel Cock (4) Filter Element (5) Filter Cup (6) Retaining Ring W1046058 Fan Belt Tension 1. Measure the deflection (A) , depressing the belt halfway between the fan drive pulley and alternator pulley at specified force 98 N (10 kgf, 22 lbs). 2.

If the measurement is not within the factory specifications, loosen the alternator mounting screws and relocate the alternator to adjust. (A) Deflection W1208957 G-11 KiSC issued 06, 2011 A Deflection (A) Factory spec. 7.0 to 9.0 mm 0.28 to 0.35 in.