43 EXCAVATOR OPERATION 7. Press the switch 2 or 3 to preset the maximum flow volume. Set the bar to the highest level, and the flow volume will be maximized. Set the bar to the lowest level (no bar displayed), and there will be no oil flow. Then press the switch 4 to go to the next port, and make the settings for all the other ports. 8. Go back to Step 3 to make settings for the next action mode. When all the settings of all the action modes have been made, press the switch 1 to return to the normal screen. (1) Switch 1 C AUX port MAX. Flow volume (1) Switch 2 (Higher flow volume) (2) Switch 3 (Lower flow volume) (3) Switch 4 (A) "MAX.
flow volume" (B) "Output interrupted" A Some attachments might not be activated even when the bar level is still somewhat above the lowest position. Or even when the bars of ports 1 and 2 (or of ports 3 and 4) are at the same level, the same speed might not be achieved. This does not indicate a machine problem, however. Readjust the bar to the optimum level according to your attachment manual. A Suppose that the same attachment is mounted on another machine. Even if the same flow control setting is made, the same speed cannot be achieved. Make an optimum setting on each machine.
A When the AUX port is not used for a long period, dirt particles can settle in the lower part of the AUX port lines. When the plugs on the AUX port lines are removed to connect attachments, drain approx. 100 cc (3.4 oz) of oil before making connections. AUX 1 port AUX 2 port MAX. flow volume (Theoretical L/min) 75 (20) 37 (9.87) MAX. pressure MPa (kgf/cm ) [psi] 17.2 (175) [2500] 17.2 (175) [2500]