65 REGULAR CHECKS AND MAINTENANCE WORK B Battery Charging B Greasing Swing Bearing Teeth 1. Pump grease with the grease gun through the grease nipple. 2. Grease at each 90 (1.58 rad.) position of the swing frame. 3. Fill with approx. 50g of grease (approx. 20 to 30 pumps with the grease gun at each position). Distribute the grease over the teeth. To avoid personal injury: A When the battery is being activated, hydrogen and oxygen gases in the battery are extremely explosive. Keep open sparks and flames away from the battery at all times, especially when charging the battery. A When charging battery, remove battery vent plugs.
A When disconnecting the cable from the battery, start with the negative terminal first. When connecting the cable to the battery, start with the positive terminal first. A Do not check battery charge by placing a metal object across the terminals. Use a voltmeter or hydrometer. 1. Make sure each electrolyte level is to the bottom of vent wells. If necessary add distilled water in a well- ventilated area. 2. The water in the electrolyte evaporates during recharging. Liquid shortage damages the battery. Excessive liquid spill damages the excavator body. 3.
To slowly charge the battery, connect the battery positive terminal to the charger’s positive terminal and the negative to the negative one. Then, recharge in the standard fashion. 4. A boost charge is only for emergencies. It will partially charge the battery at a high rate and in a short time. When using a boost-charged battery, it is necessary to recharge the battery as early as possible. Failure to do this will shorten the battery's service life. 5. When the specific gravity of electrolyte falls between 1.27 and 1.29, charge has completed. 6. When exchanging old battery for a new one, use battery of equal specification. (1) Grease nipple (for swing bearing teeth)