Kubota — Replacing Fuel Hoses and Clamps

77 REGULAR CHECKS AND MAINTENANCE WORK Stop the engine, then remove the key and wait until it has cooled down completely. 1. Open the drain plug on the bottom of the radiator and drain coolant completely. Should a recovery tank be equipped, disconnect the line from the tank floor and then open the drain cock. 2. To clean, rinse the radiator with water. 3. Close the drain plug, and fill the radiator and the recovery tank with coolant fluid. Let the engine idle for about 5 min. Stop the engine and remove the key. 4. Check the coolant level of recovery tank and add the coolant if necessary. 5. The shipped machine has been filled with 50% anti- freeze solution.

(1) Recovery tank (A) "FULL" (B) "LOW" A Do not operate the engine without coolant. A To fill the radiator system and the recovery tank, use fresh water and anti-freeze fluid. A When the anti-freeze is mixed with water, the anti- freeze mixing ratio must be less than 50%. A Tighten the radiator cap properly. If the cap is loosely or not properly fitted, overheating of the engine can result due to coolant fluid loss. (1) Drain plug B Replacing Fuel Hoses and Clamps Replace the hoses and clamps. (See "Checking Fuel and Intake Air Line" in "EVERY 200 SERVICE HOURS") (1) Radiator cap (1) Fuel lines (2) Clamp bands Cooling water Canopy Approx. 7.8 L Cabin Approx. 8.1 L