2-2 Inspection Clean the thennostat, place it in a hot-water tub, and test it for thennostatic action by heating the tub to raise the water temperature. The valve should start opening at 76.5 ± 2°C (169.7 ± 3.6°F) and be fully open at 90 ± 2°C (194 ± 3.6°F) with a valve lift of not less than 9 mm (0.35 in.). A thennostat whose valve fails to operate in this manner in the test must be replaced with a new one. E E ., > iii > ~ 9 0 Tl: Temperature [76.5° ± 2°C (169.7°± 3.6°F)1 that makes valve start opening Tz: Temperature [90° ± 2°C (194° ± 3.6°F)] that makes valve fully open with a lift of not less than 9 mm (0.35 in.) Thermostat performance curve 3.
Water pump The water pump is of centrifugal type. Its bearings are lubricated by engine oil fed from the main gallery within the crankcase. The impeller is threadedly mounted on the pump shaft. @@ 402553 1-Bolt 2-Cover 3-lmpeller 4-Unit seal 6-Bearing 7-Shaft 8-Bearing 9-Pump case 5-Snap ring 3-1 Disassembly (1) Remove pump cover (2) by loosening coverat- taching bolts (1). milO (2) Support the shaft with a stand to remove impel· ler (3). [NOTE] Impeller is threadedly mounted on shaft. The thread is of right-hand screw. - 53-